Setup and Installation - Installation
17
any convenient location in the rack with four screws. Figure 2 on page 7 pro-
vides front and rear views of the LDM-16. The nest requires access to 120Vac
power. It is equipped with a 2Amp fuse located along the rear panel.
A
TTACHING THE NETWORK LINES
The LDM-1 is designed to operate with four-wire private line networks. Both
the transmit and receive channels are polarity sensitive. The network’s + con-
ductor must always be wired to a corresponding + input at the rear panel.
Network lines are secured to appropriate screw-down terminals at the quick-
disconnect plug. The rear panel silk screening clearly labels each connector
position. The cable that connects the LDM-1 to the network should be lim-
ited to 100ft. in length.
C
ONNECTING TO THE DTE
The LDM-1 can be used with any DTE that utilizes an RS-232 interface. The
LDM-1’s operation is asynchronous. It uses the Baud rate selected by the
DTE. The DTE connects to the DB-25 female connector located at the
modem's rear panel. The pin assignments for the modem’s DB-25 connector
are listed in Figure 7 on page 31. It is wired in accordance with DCE stan-
dards.
This completes the chapter on how to set up and install the various LDM
products. The next chapter describes how to operate the modem and how to
use its self-test features.